Reload the timer when TimerControl is written, if the timer is to be
enabled. Otherwise, if an earlier write to TimerLoad was done while
periodic mode was not set, s->delta may incorrectly still have the value
of the maximum limit instead of the value written to TimerLoad.
This problem is evident on versatileap on current linux-next, which
enables TIMER_CTRL_32BIT before writing to TimerLoad and then enabling
periodic mode and starting the timer. This causes the first periodic
tick to be scheduled to occur after 0xffffffff periods, leading to a
perceived hang while the kernel waits for the first timer tick.
Signed-off-by: Rabin Vincent <[email protected]>
Signed-off-by: Aurelien Jarno <[email protected]>
case 1: freq >>= 4; break;
case 2: freq >>= 8; break;
}
- arm_timer_recalibrate(s, 0);
+ arm_timer_recalibrate(s, s->control & TIMER_CTRL_ENABLE);
ptimer_set_freq(s->timer, freq);
if (s->control & TIMER_CTRL_ENABLE) {
/* Restart the timer if still enabled. */