When the emulated RTC interrupt is no longer needed, we better disable it;
otherwise, we get a spurious interrupt whenever the timer has rolled over and
reaches the same comparator value.
Having a superfluous interrupt every five minutes doesn't hurt much, but it's
bad style anyway. ;-)
Signed-off-by: Clemens Ladisch <[email protected]>
Acked-by: "Pallipadi, Venkatesh" <[email protected]>
Cc: Andi Kleen <[email protected]>
Signed-off-by: Andrew Morton <[email protected]>
Signed-off-by: Linus Torvalds <[email protected]>
{
unsigned int cfg, cnt;
- if (!(PIE_on | AIE_on | UIE_on))
+ if (unlikely(!(PIE_on | AIE_on | UIE_on))) {
+ cfg = hpet_readl(HPET_T1_CFG);
+ cfg &= ~HPET_TN_ENABLE;
+ hpet_writel(cfg, HPET_T1_CFG);
return;
+ }
if (PIE_on && (PIE_freq > DEFAULT_RTC_INT_FREQ))
hpet_rtc_int_freq = PIE_freq;
{
unsigned int cfg, cnt;
- if (!(PIE_on | AIE_on | UIE_on))
+ if (unlikely(!(PIE_on | AIE_on | UIE_on))) {
+ cfg = hpet_readl(HPET_T1_CFG);
+ cfg &= ~HPET_TN_ENABLE;
+ hpet_writel(cfg, HPET_T1_CFG);
return;
+ }
if (PIE_on && (PIE_freq > DEFAULT_RTC_INT_FREQ))
hpet_rtc_int_freq = PIE_freq;