In cases where PHY register access is not supported, don't mislead
a caller into thinking that it is supported by returning a PHY
address. Instead, return -EOPNOTSUPP when PHY access is not
supported.
Signed-off-by: Mark Rustad <[email protected]>
Signed-off-by: Jeff Kirsher <[email protected]>
return ixgbe_ptp_set_ts_config(adapter, req);
case SIOCGHWTSTAMP:
return ixgbe_ptp_get_ts_config(adapter, req);
+ case SIOCGMIIPHY:
+ if (!adapter->hw.phy.ops.read_reg)
+ return -EOPNOTSUPP;
+ /* fall through */
default:
return mdio_mii_ioctl(&adapter->hw.phy.mdio, if_mii(req), cmd);
}