Add missing reg minItems as based on current binding document
only ethernet MAC IO space is a supported configuration.
There is a bug in schema, current examples contain 64-bit
addressing as well as 32-bit addressing. The schema validation
does pass incidentally considering one 64-bit reg address as
two 32-bit reg address entries. If we change axi_ethernet_eth1
example node reg addressing to 32-bit schema validation reports:
Documentation/devicetree/bindings/net/xlnx,axi-ethernet.example.dtb:
ethernet@
40000000: reg: [[
1073741824, 262144]] is too short
To fix it add missing reg minItems constraints and to make things clearer
stick to 32-bit addressing in examples.
Fixes: cbb1ca6d5f9a ("dt-bindings: net: xlnx,axi-ethernet: convert bindings document to yaml")
Signed-off-by: Ravikanth Tuniki <[email protected]>
Signed-off-by: Radhey Shyam Pandey <[email protected]>
Acked-by: Conor Dooley <[email protected]>
Link: https://patch.msgid.link/[email protected]
Signed-off-by: Paolo Abeni <[email protected]>
and length of the AXI DMA controller IO space, unless
axistream-connected is specified, in which case the reg
attribute of the node referenced by it is used.
+ minItems: 1
maxItems: 2
interrupts:
clock-names = "s_axi_lite_clk", "axis_clk", "ref_clk", "mgt_clk";
clocks = <&axi_clk>, <&axi_clk>, <&pl_enet_ref_clk>, <&mgt_clk>;
phy-mode = "mii";
- reg = <0x00 0x40000000 0x00 0x40000>;
+ reg = <0x40000000 0x40000>;
xlnx,rxcsum = <0x2>;
xlnx,rxmem = <0x800>;
xlnx,txcsum = <0x2>;