Fix slab-out-of-bounds read in the interrupt-URB completion handler.
The boundary condition should be (length - 1) as we access
data[position + 1].
Reported-and-tested-by: [email protected]
Signed-off-by: Qiujun Huang <[email protected]>
Fixes: 1da177e4c3f4 ("Linux-2.6.12-rc2")
Cc: stable <[email protected]>
Signed-off-by: Johan Hovold <[email protected]>
/* grab the txcredits for the ports if available */
position = 2;
portNumber = 0;
- while ((position < length) &&
+ while ((position < length - 1) &&
(portNumber < edge_serial->serial->num_ports)) {
txCredits = data[position] | (data[position+1] << 8);
if (txCredits) {