[linux.git] / drivers / thermal / gov_power_allocator.c
1 // SPDX-License-Identifier: GPL-2.0
2 /*
3  * A power allocator to manage temperature
4  *
5  * Copyright (C) 2014 ARM Ltd.
6  *
7  */
8
9 #define pr_fmt(fmt) "Power allocator: " fmt
10
11 #include <linux/slab.h>
12 #include <linux/thermal.h>
13
14 #define CREATE_TRACE_POINTS
15 #include "thermal_trace_ipa.h"
16
17 #include "thermal_core.h"
18
19 #define FRAC_BITS 10
20 #define int_to_frac(x) ((x) << FRAC_BITS)
21 #define frac_to_int(x) ((x) >> FRAC_BITS)
22
23 /**
24  * mul_frac() - multiply two fixed-point numbers
25  * @x:  first multiplicand
26  * @y:  second multiplicand
27  *
28  * Return: the result of multiplying two fixed-point numbers.  The
29  * result is also a fixed-point number.
30  */
31 static inline s64 mul_frac(s64 x, s64 y)
32 {
33         return (x * y) >> FRAC_BITS;
34 }
35
36 /**
37  * div_frac() - divide two fixed-point numbers
38  * @x:  the dividend
39  * @y:  the divisor
40  *
41  * Return: the result of dividing two fixed-point numbers.  The
42  * result is also a fixed-point number.
43  */
44 static inline s64 div_frac(s64 x, s64 y)
45 {
46         return div_s64(x << FRAC_BITS, y);
47 }
48
49 /**
50  * struct power_actor - internal power information for power actor
51  * @req_power:          requested power value (not weighted)
52  * @max_power:          max allocatable power for this actor
53  * @granted_power:      granted power for this actor
54  * @extra_actor_power:  extra power that this actor can receive
55  * @weighted_req_power: weighted requested power as input to IPA
56  */
57 struct power_actor {
58         u32 req_power;
59         u32 max_power;
60         u32 granted_power;
61         u32 extra_actor_power;
62         u32 weighted_req_power;
63 };
64
65 /**
66  * struct power_allocator_params - parameters for the power allocator governor
67  * @allocated_tzp:      whether we have allocated tzp for this thermal zone and
68  *                      it needs to be freed on unbind
69  * @update_cdevs:       whether or not update cdevs on the next run
70  * @err_integral:       accumulated error in the PID controller.
71  * @prev_err:   error in the previous iteration of the PID controller.
72  *              Used to calculate the derivative term.
73  * @sustainable_power:  Sustainable power (heat) that this thermal zone can
74  *                      dissipate
75  * @trip_switch_on:     first passive trip point of the thermal zone.  The
76  *                      governor switches on when this trip point is crossed.
77  *                      If the thermal zone only has one passive trip point,
78  *                      @trip_switch_on should be NULL.
79  * @trip_max:           last passive trip point of the thermal zone. The
80  *                      temperature we are controlling for.
81  * @total_weight:       Sum of all thermal instances weights
82  * @num_actors:         number of cooling devices supporting IPA callbacks
83  * @buffer_size:        internal buffer size, to avoid runtime re-calculation
84  * @power:              buffer for all power actors internal power information
85  */
86 struct power_allocator_params {
87         bool allocated_tzp;
88         bool update_cdevs;
89         s64 err_integral;
90         s32 prev_err;
91         u32 sustainable_power;
92         const struct thermal_trip *trip_switch_on;
93         const struct thermal_trip *trip_max;
94         int total_weight;
95         unsigned int num_actors;
96         unsigned int buffer_size;
97         struct power_actor *power;
98 };
99
100 static bool power_actor_is_valid(struct power_allocator_params *params,
101                                  struct thermal_instance *instance)
102 {
103         return (instance->trip == params->trip_max &&
104                  cdev_is_power_actor(instance->cdev));
105 }
106
107 /**
108  * estimate_sustainable_power() - Estimate the sustainable power of a thermal zone
109  * @tz: thermal zone we are operating in
110  *
111  * For thermal zones that don't provide a sustainable_power in their
112  * thermal_zone_params, estimate one.  Calculate it using the minimum
113  * power of all the cooling devices as that gives a valid value that
114  * can give some degree of functionality.  For optimal performance of
115  * this governor, provide a sustainable_power in the thermal zone's
116  * thermal_zone_params.
117  */
118 static u32 estimate_sustainable_power(struct thermal_zone_device *tz)
119 {
120         struct power_allocator_params *params = tz->governor_data;
121         struct thermal_cooling_device *cdev;
122         struct thermal_instance *instance;
123         u32 sustainable_power = 0;
124         u32 min_power;
125
126         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
127                 if (!power_actor_is_valid(params, instance))
128                         continue;
129
130                 cdev = instance->cdev;
131                 if (cdev->ops->state2power(cdev, instance->upper, &min_power))
132                         continue;
133
134                 sustainable_power += min_power;
135         }
136
137         return sustainable_power;
138 }
139
140 /**
141  * estimate_pid_constants() - Estimate the constants for the PID controller
142  * @tz:         thermal zone for which to estimate the constants
143  * @sustainable_power:  sustainable power for the thermal zone
144  * @trip_switch_on:     trip point for the switch on temperature
145  * @control_temp:       target temperature for the power allocator governor
146  *
147  * This function is used to update the estimation of the PID
148  * controller constants in struct thermal_zone_parameters.
149  */
150 static void estimate_pid_constants(struct thermal_zone_device *tz,
151                                    u32 sustainable_power,
152                                    const struct thermal_trip *trip_switch_on,
153                                    int control_temp)
154 {
155         u32 temperature_threshold = control_temp;
156         s32 k_i;
157
158         if (trip_switch_on)
159                 temperature_threshold -= trip_switch_on->temperature;
160
161         /*
162          * estimate_pid_constants() tries to find appropriate default
163          * values for thermal zones that don't provide them. If a
164          * system integrator has configured a thermal zone with two
165          * passive trip points at the same temperature, that person
166          * hasn't put any effort to set up the thermal zone properly
167          * so just give up.
168          */
169         if (!temperature_threshold)
170                 return;
171
172         tz->tzp->k_po = int_to_frac(sustainable_power) /
173                 temperature_threshold;
174
175         tz->tzp->k_pu = int_to_frac(2 * sustainable_power) /
176                 temperature_threshold;
177
178         k_i = tz->tzp->k_pu / 10;
179         tz->tzp->k_i = k_i > 0 ? k_i : 1;
180
181         /*
182          * The default for k_d and integral_cutoff is 0, so we can
183          * leave them as they are.
184          */
185 }
186
187 /**
188  * get_sustainable_power() - Get the right sustainable power
189  * @tz:         thermal zone for which to estimate the constants
190  * @params:     parameters for the power allocator governor
191  * @control_temp:       target temperature for the power allocator governor
192  *
193  * This function is used for getting the proper sustainable power value based
194  * on variables which might be updated by the user sysfs interface. If that
195  * happen the new value is going to be estimated and updated. It is also used
196  * after thermal zone binding, where the initial values where set to 0.
197  */
198 static u32 get_sustainable_power(struct thermal_zone_device *tz,
199                                  struct power_allocator_params *params,
200                                  int control_temp)
201 {
202         u32 sustainable_power;
203
204         if (!tz->tzp->sustainable_power)
205                 sustainable_power = estimate_sustainable_power(tz);
206         else
207                 sustainable_power = tz->tzp->sustainable_power;
208
209         /* Check if it's init value 0 or there was update via sysfs */
210         if (sustainable_power != params->sustainable_power) {
211                 estimate_pid_constants(tz, sustainable_power,
212                                        params->trip_switch_on, control_temp);
213
214                 /* Do the estimation only once and make available in sysfs */
215                 tz->tzp->sustainable_power = sustainable_power;
216                 params->sustainable_power = sustainable_power;
217         }
218
219         return sustainable_power;
220 }
221
222 /**
223  * pid_controller() - PID controller
224  * @tz: thermal zone we are operating in
225  * @control_temp:       the target temperature in millicelsius
226  * @max_allocatable_power:      maximum allocatable power for this thermal zone
227  *
228  * This PID controller increases the available power budget so that the
229  * temperature of the thermal zone gets as close as possible to
230  * @control_temp and limits the power if it exceeds it.  k_po is the
231  * proportional term when we are overshooting, k_pu is the
232  * proportional term when we are undershooting.  integral_cutoff is a
233  * threshold below which we stop accumulating the error.  The
234  * accumulated error is only valid if the requested power will make
235  * the system warmer.  If the system is mostly idle, there's no point
236  * in accumulating positive error.
237  *
238  * Return: The power budget for the next period.
239  */
240 static u32 pid_controller(struct thermal_zone_device *tz,
241                           int control_temp,
242                           u32 max_allocatable_power)
243 {
244         struct power_allocator_params *params = tz->governor_data;
245         s64 p, i, d, power_range;
246         s32 err, max_power_frac;
247         u32 sustainable_power;
248
249         max_power_frac = int_to_frac(max_allocatable_power);
250
251         sustainable_power = get_sustainable_power(tz, params, control_temp);
252
253         err = control_temp - tz->temperature;
254         err = int_to_frac(err);
255
256         /* Calculate the proportional term */
257         p = mul_frac(err < 0 ? tz->tzp->k_po : tz->tzp->k_pu, err);
258
259         /*
260          * Calculate the integral term
261          *
262          * if the error is less than cut off allow integration (but
263          * the integral is limited to max power)
264          */
265         i = mul_frac(tz->tzp->k_i, params->err_integral);
266
267         if (err < int_to_frac(tz->tzp->integral_cutoff)) {
268                 s64 i_next = i + mul_frac(tz->tzp->k_i, err);
269
270                 if (abs(i_next) < max_power_frac) {
271                         i = i_next;
272                         params->err_integral += err;
273                 }
274         }
275
276         /*
277          * Calculate the derivative term
278          *
279          * We do err - prev_err, so with a positive k_d, a decreasing
280          * error (i.e. driving closer to the line) results in less
281          * power being applied, slowing down the controller)
282          */
283         d = mul_frac(tz->tzp->k_d, err - params->prev_err);
284         d = div_frac(d, jiffies_to_msecs(tz->passive_delay_jiffies));
285         params->prev_err = err;
286
287         power_range = p + i + d;
288
289         /* feed-forward the known sustainable dissipatable power */
290         power_range = sustainable_power + frac_to_int(power_range);
291
292         power_range = clamp(power_range, (s64)0, (s64)max_allocatable_power);
293
294         trace_thermal_power_allocator_pid(tz, frac_to_int(err),
295                                           frac_to_int(params->err_integral),
296                                           frac_to_int(p), frac_to_int(i),
297                                           frac_to_int(d), power_range);
298
299         return power_range;
300 }
301
302 /**
303  * power_actor_set_power() - limit the maximum power a cooling device consumes
304  * @cdev:       pointer to &thermal_cooling_device
305  * @instance:   thermal instance to update
306  * @power:      the power in milliwatts
307  *
308  * Set the cooling device to consume at most @power milliwatts. The limit is
309  * expected to be a cap at the maximum power consumption.
310  *
311  * Return: 0 on success, -EINVAL if the cooling device does not
312  * implement the power actor API or -E* for other failures.
313  */
314 static int
315 power_actor_set_power(struct thermal_cooling_device *cdev,
316                       struct thermal_instance *instance, u32 power)
317 {
318         unsigned long state;
319         int ret;
320
321         ret = cdev->ops->power2state(cdev, power, &state);
322         if (ret)
323                 return ret;
324
325         instance->target = clamp_val(state, instance->lower, instance->upper);
326         mutex_lock(&cdev->lock);
327         __thermal_cdev_update(cdev);
328         mutex_unlock(&cdev->lock);
329
330         return 0;
331 }
332
333 /**
334  * divvy_up_power() - divvy the allocated power between the actors
335  * @power:              buffer for all power actors internal power information
336  * @num_actors:         number of power actors in this thermal zone
337  * @total_req_power:    sum of all weighted requested power for all actors
338  * @power_range:        total allocated power
339  *
340  * This function divides the total allocated power (@power_range)
341  * fairly between the actors.  It first tries to give each actor a
342  * share of the @power_range according to how much power it requested
343  * compared to the rest of the actors.  For example, if only one actor
344  * requests power, then it receives all the @power_range.  If
345  * three actors each requests 1mW, each receives a third of the
346  * @power_range.
347  *
348  * If any actor received more than their maximum power, then that
349  * surplus is re-divvied among the actors based on how far they are
350  * from their respective maximums.
351  */
352 static void divvy_up_power(struct power_actor *power, int num_actors,
353                            u32 total_req_power, u32 power_range)
354 {
355         u32 capped_extra_power = 0;
356         u32 extra_power = 0;
357         int i;
358
359         /*
360          * Prevent division by 0 if none of the actors request power.
361          */
362         if (!total_req_power)
363                 total_req_power = 1;
364
365         for (i = 0; i < num_actors; i++) {
366                 struct power_actor *pa = &power[i];
367                 u64 req_range = (u64)pa->req_power * power_range;
368
369                 pa->granted_power = DIV_ROUND_CLOSEST_ULL(req_range,
370                                                           total_req_power);
371
372                 if (pa->granted_power > pa->max_power) {
373                         extra_power += pa->granted_power - pa->max_power;
374                         pa->granted_power = pa->max_power;
375                 }
376
377                 pa->extra_actor_power = pa->max_power - pa->granted_power;
378                 capped_extra_power += pa->extra_actor_power;
379         }
380
381         if (!extra_power || !capped_extra_power)
382                 return;
383
384         /*
385          * Re-divvy the reclaimed extra among actors based on
386          * how far they are from the max
387          */
388         extra_power = min(extra_power, capped_extra_power);
389
390         for (i = 0; i < num_actors; i++) {
391                 struct power_actor *pa = &power[i];
392                 u64 extra_range = pa->extra_actor_power;
393
394                 extra_range *= extra_power;
395                 pa->granted_power += DIV_ROUND_CLOSEST_ULL(extra_range,
396                                                 capped_extra_power);
397         }
398 }
399
400 static void allocate_power(struct thermal_zone_device *tz, int control_temp)
401 {
402         struct power_allocator_params *params = tz->governor_data;
403         unsigned int num_actors = params->num_actors;
404         struct power_actor *power = params->power;
405         struct thermal_cooling_device *cdev;
406         struct thermal_instance *instance;
407         u32 total_weighted_req_power = 0;
408         u32 max_allocatable_power = 0;
409         u32 total_granted_power = 0;
410         u32 total_req_power = 0;
411         u32 power_range, weight;
412         int i = 0, ret;
413
414         if (!num_actors)
415                 return;
416
417         /* Clean all buffers for new power estimations */
418         memset(power, 0, params->buffer_size);
419
420         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
421                 struct power_actor *pa = &power[i];
422
423                 if (!power_actor_is_valid(params, instance))
424                         continue;
425
426                 cdev = instance->cdev;
427
428                 ret = cdev->ops->get_requested_power(cdev, &pa->req_power);
429                 if (ret)
430                         continue;
431
432                 if (!params->total_weight)
433                         weight = 1 << FRAC_BITS;
434                 else
435                         weight = instance->weight;
436
437                 pa->weighted_req_power = frac_to_int(weight * pa->req_power);
438
439                 ret = cdev->ops->state2power(cdev, instance->lower,
440                                              &pa->max_power);
441                 if (ret)
442                         continue;
443
444                 total_req_power += pa->req_power;
445                 max_allocatable_power += pa->max_power;
446                 total_weighted_req_power += pa->weighted_req_power;
447
448                 i++;
449         }
450
451         power_range = pid_controller(tz, control_temp, max_allocatable_power);
452
453         divvy_up_power(power, num_actors, total_weighted_req_power,
454                        power_range);
455
456         i = 0;
457         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
458                 struct power_actor *pa = &power[i];
459
460                 if (!power_actor_is_valid(params, instance))
461                         continue;
462
463                 power_actor_set_power(instance->cdev, instance,
464                                       pa->granted_power);
465                 total_granted_power += pa->granted_power;
466
467                 trace_thermal_power_actor(tz, i, pa->req_power,
468                                           pa->granted_power);
469                 i++;
470         }
471
472         trace_thermal_power_allocator(tz, total_req_power, total_granted_power,
473                                       num_actors, power_range,
474                                       max_allocatable_power, tz->temperature,
475                                       control_temp - tz->temperature);
476 }
477
478 /**
479  * get_governor_trips() - get the two trip points that are key for this governor
480  * @tz: thermal zone to operate on
481  * @params:     pointer to private data for this governor
482  *
483  * The power allocator governor works optimally with two trips points:
484  * a "switch on" trip point and a "maximum desired temperature".  These
485  * are defined as the first and last passive trip points.
486  *
487  * If there is only one trip point, then that's considered to be the
488  * "maximum desired temperature" trip point and the governor is always
489  * on.  If there are no passive or active trip points, then the
490  * governor won't do anything.  In fact, its throttle function
491  * won't be called at all.
492  */
493 static void get_governor_trips(struct thermal_zone_device *tz,
494                                struct power_allocator_params *params)
495 {
496         const struct thermal_trip *first_passive = NULL;
497         const struct thermal_trip *last_passive = NULL;
498         const struct thermal_trip *last_active = NULL;
499         const struct thermal_trip_desc *td;
500
501         for_each_trip_desc(tz, td) {
502                 const struct thermal_trip *trip = &td->trip;
503
504                 switch (trip->type) {
505                 case THERMAL_TRIP_PASSIVE:
506                         if (!first_passive) {
507                                 first_passive = trip;
508                                 break;
509                         }
510                         last_passive = trip;
511                         break;
512                 case THERMAL_TRIP_ACTIVE:
513                         last_active = trip;
514                         break;
515                 default:
516                         break;
517                 }
518         }
519
520         if (last_passive) {
521                 params->trip_switch_on = first_passive;
522                 params->trip_max = last_passive;
523         } else if (first_passive) {
524                 params->trip_switch_on = NULL;
525                 params->trip_max = first_passive;
526         } else {
527                 params->trip_switch_on = NULL;
528                 params->trip_max = last_active;
529         }
530 }
531
532 static void reset_pid_controller(struct power_allocator_params *params)
533 {
534         params->err_integral = 0;
535         params->prev_err = 0;
536 }
537
538 static void allow_maximum_power(struct thermal_zone_device *tz)
539 {
540         struct power_allocator_params *params = tz->governor_data;
541         struct thermal_cooling_device *cdev;
542         struct thermal_instance *instance;
543         u32 req_power;
544
545         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
546                 if (!power_actor_is_valid(params, instance))
547                         continue;
548
549                 cdev = instance->cdev;
550
551                 instance->target = 0;
552                 mutex_lock(&cdev->lock);
553                 /*
554                  * Call for updating the cooling devices local stats and avoid
555                  * periods of dozen of seconds when those have not been
556                  * maintained.
557                  */
558                 cdev->ops->get_requested_power(cdev, &req_power);
559
560                 if (params->update_cdevs)
561                         __thermal_cdev_update(cdev);
562
563                 mutex_unlock(&cdev->lock);
564         }
565 }
566
567 /**
568  * check_power_actors() - Check all cooling devices and warn when they are
569  *                      not power actors
570  * @tz:         thermal zone to operate on
571  * @params:     power allocator private data
572  *
573  * Check all cooling devices in the @tz and warn every time they are missing
574  * power actor API. The warning should help to investigate the issue, which
575  * could be e.g. lack of Energy Model for a given device.
576  *
577  * If all of the cooling devices currently attached to @tz implement the power
578  * actor API, return the number of them (which may be 0, because some cooling
579  * devices may be attached later). Otherwise, return -EINVAL.
580  */
581 static int check_power_actors(struct thermal_zone_device *tz,
582                               struct power_allocator_params *params)
583 {
584         struct thermal_instance *instance;
585         int ret = 0;
586
587         list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
588                 if (instance->trip != params->trip_max)
589                         continue;
590
591                 if (!cdev_is_power_actor(instance->cdev)) {
592                         dev_warn(&tz->device, "power_allocator: %s is not a power actor\n",
593                                  instance->cdev->type);
594                         return -EINVAL;
595                 }
596                 ret++;
597         }
598
599         return ret;
600 }
601
602 static int allocate_actors_buffer(struct power_allocator_params *params,
603                                   int num_actors)
604 {
605         int ret;
606
607         kfree(params->power);
608
609         /* There might be no cooling devices yet. */
610         if (!num_actors) {
611                 ret = 0;
612                 goto clean_state;
613         }
614
615         params->power = kcalloc(num_actors, sizeof(struct power_actor),
616                                 GFP_KERNEL);
617         if (!params->power) {
618                 ret = -ENOMEM;
619                 goto clean_state;
620         }
621
622         params->num_actors = num_actors;
623         params->buffer_size = num_actors * sizeof(struct power_actor);
624
625         return 0;
626
627 clean_state:
628         params->num_actors = 0;
629         params->buffer_size = 0;
630         params->power = NULL;
631         return ret;
632 }
633
634 static void power_allocator_update_tz(struct thermal_zone_device *tz,
635                                       enum thermal_notify_event reason)
636 {
637         struct power_allocator_params *params = tz->governor_data;
638         struct thermal_instance *instance;
639         int num_actors = 0;
640
641         switch (reason) {
642         case THERMAL_TZ_BIND_CDEV:
643         case THERMAL_TZ_UNBIND_CDEV:
644                 list_for_each_entry(instance, &tz->thermal_instances, tz_node)
645                         if (power_actor_is_valid(params, instance))
646                                 num_actors++;
647
648                 if (num_actors == params->num_actors)
649                         return;
650
651                 allocate_actors_buffer(params, num_actors);
652                 break;
653         case THERMAL_INSTANCE_WEIGHT_CHANGED:
654                 params->total_weight = 0;
655                 list_for_each_entry(instance, &tz->thermal_instances, tz_node)
656                         if (power_actor_is_valid(params, instance))
657                                 params->total_weight += instance->weight;
658                 break;
659         default:
660                 break;
661         }
662 }
663
664 /**
665  * power_allocator_bind() - bind the power_allocator governor to a thermal zone
666  * @tz: thermal zone to bind it to
667  *
668  * Initialize the PID controller parameters and bind it to the thermal
669  * zone.
670  *
671  * Return: 0 on success, or -ENOMEM if we ran out of memory, or -EINVAL
672  * when there are unsupported cooling devices in the @tz.
673  */
674 static int power_allocator_bind(struct thermal_zone_device *tz)
675 {
676         struct power_allocator_params *params;
677         int ret;
678
679         params = kzalloc(sizeof(*params), GFP_KERNEL);
680         if (!params)
681                 return -ENOMEM;
682
683         get_governor_trips(tz, params);
684
685         ret = check_power_actors(tz, params);
686         if (ret < 0) {
687                 dev_warn(&tz->device, "power_allocator: binding failed\n");
688                 kfree(params);
689                 return ret;
690         }
691
692         ret = allocate_actors_buffer(params, ret);
693         if (ret) {
694                 dev_warn(&tz->device, "power_allocator: allocation failed\n");
695                 kfree(params);
696                 return ret;
697         }
698
699         if (!tz->tzp) {
700                 tz->tzp = kzalloc(sizeof(*tz->tzp), GFP_KERNEL);
701                 if (!tz->tzp) {
702                         ret = -ENOMEM;
703                         goto free_params;
704                 }
705
706                 params->allocated_tzp = true;
707         }
708
709         if (!tz->tzp->sustainable_power)
710                 dev_warn(&tz->device, "power_allocator: sustainable_power will be estimated\n");
711         else
712                 params->sustainable_power = tz->tzp->sustainable_power;
713
714         if (params->trip_max)
715                 estimate_pid_constants(tz, tz->tzp->sustainable_power,
716                                        params->trip_switch_on,
717                                        params->trip_max->temperature);
718
719         reset_pid_controller(params);
720
721         tz->governor_data = params;
722
723         return 0;
724
725 free_params:
726         kfree(params->power);
727         kfree(params);
728
729         return ret;
730 }
731
732 static void power_allocator_unbind(struct thermal_zone_device *tz)
733 {
734         struct power_allocator_params *params = tz->governor_data;
735
736         dev_dbg(&tz->device, "Unbinding from thermal zone %d\n", tz->id);
737
738         if (params->allocated_tzp) {
739                 kfree(tz->tzp);
740                 tz->tzp = NULL;
741         }
742
743         kfree(params->power);
744         kfree(tz->governor_data);
745         tz->governor_data = NULL;
746 }
747
748 static void power_allocator_manage(struct thermal_zone_device *tz)
749 {
750         struct power_allocator_params *params = tz->governor_data;
751         const struct thermal_trip *trip = params->trip_switch_on;
752
753         lockdep_assert_held(&tz->lock);
754
755         if (trip && tz->temperature < trip->temperature) {
756                 reset_pid_controller(params);
757                 allow_maximum_power(tz);
758                 params->update_cdevs = false;
759                 return;
760         }
761
762         if (!params->trip_max)
763                 return;
764
765         allocate_power(tz, params->trip_max->temperature);
766         params->update_cdevs = true;
767 }
768
769 static struct thermal_governor thermal_gov_power_allocator = {
770         .name           = "power_allocator",
771         .bind_to_tz     = power_allocator_bind,
772         .unbind_from_tz = power_allocator_unbind,
773         .manage         = power_allocator_manage,
774         .update_tz      = power_allocator_update_tz,
775 };
776 THERMAL_GOVERNOR_DECLARE(thermal_gov_power_allocator);