Not all OPP entries fit into a single word. In particular NVIDIA Tegra OPP
tables use multi-word names. Allow OPP entry to have multi-worded name
separated by hyphen. This silences DT checker warnings about wrong naming
scheme.
Reviewed-by: David Heidelberg <[email protected]>
Signed-off-by: Dmitry Osipenko <[email protected]>
Signed-off-by: Viresh Kumar <[email protected]>
type: boolean
patternProperties:
- '^opp-?[0-9]+$':
+ '^opp(-?[0-9]+)*$':
type: object
description:
One or more OPP nodes describing voltage-current-frequency combinations.