@code{-device @var{driver},?}.
ETEXI
+DEFHEADING()
+
DEFHEADING(File system options:)
DEF("fsdev", HAS_ARG, QEMU_OPTION_fsdev,
- "-fsdev local,id=id,path=path,security_model=[mapped|passthrough|none]\n",
+ "-fsdev fsdriver,id=id,path=path,[security_model={mapped|passthrough|none}]\n"
+ " [,writeout=immediate][,readonly]\n",
QEMU_ARCH_ALL)
STEXI
-The general form of a File system device option is:
-@table @option
-
-@item -fsdev @var{fstype} ,id=@var{id} [,@var{options}]
+@item -fsdev @var{fsdriver},id=@var{id},path=@var{path},[security_model=@var{security_model}][,writeout=@var{writeout}][,readonly]
@findex -fsdev
-Fstype is one of:
-@option{local},
-The specific Fstype will determine the applicable options.
-
-Options to each backend are described below.
-
-@item -fsdev local ,id=@var{id} ,path=@var{path} ,security_model=@var{security_model}
-
-Create a file-system-"device" for local-filesystem.
-
-@option{local} is only available on Linux.
-
-@option{path} specifies the path to be exported. @option{path} is required.
-
-@option{security_model} specifies the security model to be followed.
-@option{security_model} is required.
+Define a new file system device. Valid options are:
+@table @option
+@item @var{fsdriver}
+This option specifies the fs driver backend to use.
+Currently "local" and "handle" file system drivers are supported.
+@item id=@var{id}
+Specifies identifier for this device
+@item path=@var{path}
+Specifies the export path for the file system device. Files under
+this path will be available to the 9p client on the guest.
+@item security_model=@var{security_model}
+Specifies the security model to be used for this export path.
+Supported security models are "passthrough", "mapped" and "none".
+In "passthrough" security model, files are stored using the same
+credentials as they are created on the guest. This requires qemu
+to run as root. In "mapped" security model, some of the file
+attributes like uid, gid, mode bits and link target are stored as
+file attributes. Directories exported by this security model cannot
+interact with other unix tools. "none" security model is same as
+passthrough except the sever won't report failures if it fails to
+set file attributes like ownership. Security model is mandatory
+only for local fsdriver. Other fsdrivers (like handle) don't take
+security model as a parameter.
+@item writeout=@var{writeout}
+This is an optional argument. The only supported value is "immediate".
+This means that host page cache will be used to read and write data but
+write notification will be sent to the guest only when the data has been
+reported as written by the storage subsystem.
+@item readonly
+Enables exporting 9p share as a readonly mount for guests. By default
+read-write access is given.
+@end table
+-fsdev option is used along with -device driver "virtio-9p-pci".
+@item -device virtio-9p-pci,fsdev=@var{id},mount_tag=@var{mount_tag}
+Options for virtio-9p-pci driver are:
+@table @option
+@item fsdev=@var{id}
+Specifies the id value specified along with -fsdev option
+@item mount_tag=@var{mount_tag}
+Specifies the tag name to be used by the guest to mount this export point
@end table
+
ETEXI
+DEFHEADING()
+
DEFHEADING(Virtual File system pass-through options:)
DEF("virtfs", HAS_ARG, QEMU_OPTION_virtfs,
- "-virtfs local,path=path,mount_tag=tag,security_model=[mapped|passthrough|none]\n",
+ "-virtfs local,path=path,mount_tag=tag,security_model=[mapped|passthrough|none]\n"
+ " [,writeout=immediate][,readonly]\n",
QEMU_ARCH_ALL)
STEXI
-The general form of a Virtual File system pass-through option is:
-@table @option
-
-@item -virtfs @var{fstype} [,@var{options}]
+@item -virtfs @var{fsdriver},path=@var{path},mount_tag=@var{mount_tag},security_model=@var{security_model}[,writeout=@var{writeout}][,readonly]
@findex -virtfs
-Fstype is one of:
-@option{local},
-The specific Fstype will determine the applicable options.
-
-Options to each backend are described below.
-
-@item -virtfs local ,path=@var{path} ,mount_tag=@var{mount_tag} ,security_model=@var{security_model}
-
-Create a Virtual file-system-pass through for local-filesystem.
-
-@option{local} is only available on Linux.
-
-@option{path} specifies the path to be exported. @option{path} is required.
-
-@option{security_model} specifies the security model to be followed.
-@option{security_model} is required.
-
-
-@option{mount_tag} specifies the tag with which the exported file is mounted.
-@option{mount_tag} is required.
+The general form of a Virtual File system pass-through options are:
+@table @option
+@item @var{fsdriver}
+This option specifies the fs driver backend to use.
+Currently "local" and "handle" file system drivers are supported.
+@item id=@var{id}
+Specifies identifier for this device
+@item path=@var{path}
+Specifies the export path for the file system device. Files under
+this path will be available to the 9p client on the guest.
+@item security_model=@var{security_model}
+Specifies the security model to be used for this export path.
+Supported security models are "passthrough", "mapped" and "none".
+In "passthrough" security model, files are stored using the same
+credentials as they are created on the guest. This requires qemu
+to run as root. In "mapped" security model, some of the file
+attributes like uid, gid, mode bits and link target are stored as
+file attributes. Directories exported by this security model cannot
+interact with other unix tools. "none" security model is same as
+passthrough except the sever won't report failures if it fails to
+set file attributes like ownership. Security model is mandatory only
+for local fsdriver. Other fsdrivers (like handle) don't take security
+model as a parameter.
+@item writeout=@var{writeout}
+This is an optional argument. The only supported value is "immediate".
+This means that host page cache will be used to read and write data but
+write notification will be sent to the guest only when the data has been
+reported as written by the storage subsystem.
+@item readonly
+Enables exporting 9p share as a readonly mount for guests. By default
+read-write access is given.
@end table
ETEXI
+DEF("virtfs_synth", 0, QEMU_OPTION_virtfs_synth,
+ "-virtfs_synth Create synthetic file system image\n",
+ QEMU_ARCH_ALL)
+STEXI
+@item -virtfs_synth
+@findex -virtfs_synth
+Create synthetic file system image
+ETEXI
+
DEFHEADING()
DEF("name", HAS_ARG, QEMU_OPTION_name,
Then @file{@var{dir}} can be accessed in @file{\\smbserver\qemu}.
-Note that a SAMBA server must be installed on the host OS in
-@file{/usr/sbin/smbd}. QEMU was tested successfully with smbd versions from
-Red Hat 9, Fedora Core 3 and OpenSUSE 11.x.
+Note that a SAMBA server must be installed on the host OS.
+QEMU was tested successfully with smbd versions from Red Hat 9,
+Fedora Core 3 and OpenSUSE 11.x.
@item hostfwd=[tcp|udp]:[@var{hostaddr}]:@var{hostport}-[@var{guestaddr}]:@var{guestport}
Redirect incoming TCP or UDP connections to the host port @var{hostport} to
Connect VLAN @var{n} to PORT @var{n} of a vde switch running on host and
listening for incoming connections on @var{socketpath}. Use GROUP @var{groupname}
and MODE @var{octalmode} to change default ownership and permissions for
-communication port. This option is available only if QEMU has been compiled
+communication port. This option is only available if QEMU has been compiled
with vde support enabled.
Example:
@option{path} specifies the path to the parallel port device. @option{path} is
required.
-#if defined(CONFIG_SPICE)
@item -chardev spicevmc ,id=@var{id} ,debug=@var{debug}, name=@var{name}
+@option{spicevmc} is only available when spice support is built in.
+
@option{debug} debug level for spicevmc
@option{name} name of spice channel to connect to
Connect to a spice virtual machine channel, such as vdiport.
-#endif
@end table
ETEXI
Set OpenBIOS nvram @var{variable} to given @var{value} (PPC, SPARC only).
ETEXI
DEF("semihosting", 0, QEMU_OPTION_semihosting,
- "-semihosting semihosting mode\n", QEMU_ARCH_ARM | QEMU_ARCH_M68K)
+ "-semihosting semihosting mode\n", QEMU_ARCH_ARM | QEMU_ARCH_M68K | QEMU_ARCH_XTENSA)
STEXI
@item -semihosting
@findex -semihosting
-Semihosting mode (ARM, M68K only).
+Semihosting mode (ARM, M68K, Xtensa only).
ETEXI
DEF("old-param", 0, QEMU_OPTION_old_param,
"-old-param old param mode\n", QEMU_ARCH_ARM)
Immediately enable events listed in @var{file}.
The file must contain one event name (as listed in the @var{trace-events} file)
per line.
-
-This option is only available when using the @var{simple} tracing backend.
+This option is only available if QEMU has been compiled with
+either @var{simple} or @var{stderr} tracing backend.
@item file=@var{file}
Log output traces to @var{file}.
-This option is only available when using the @var{simple} tracing backend.
+This option is only available if QEMU has been compiled with
+the @var{simple} tracing backend.
@end table
ETEXI