mwifiex: fix negative cmd_pending count
cmd_pending is increased in mwifiex_wait_queue_complete() and
decreased in mwifiex_complete_cmd() currently.
If there are two or more commands in the cmd_pending_q the main
worker thread will pick up next command from cmd_pending_q
automatically after finishing current command. As a result
mwifiex_wait_queue_complete() will not be called because
the command is alreay completed. This leads to a negative
number in cmd_pending count.
Fix it by increasing cmd_pending when a cmd is queued into
cmd_pending_q and decreasing when that cmd is recycled. For scan
commands we don't perform inc/dec operations until it's moved
from scan_pending_q to cmd_pending_q. This covers both
synchronous and asynchronous commands.
Reported-by: Daniel Drake <[email protected]>
Tested-by: Daniel Drake <[email protected]>
Tested-by: Marco Cesarano <[email protected]>
Signed-off-by: Bing Zhao <[email protected]>
Signed-off-by: John W. Linville <[email protected]>