1 | Kernel drivers ltc2947-i2c and ltc2947-spi |
2 | ========================================== | |
3 | ||
4 | Supported chips: | |
5 | ||
6 | * Analog Devices LTC2947 | |
7 | ||
8 | Prefix: 'ltc2947' | |
9 | ||
10 | Addresses scanned: - | |
11 | ||
12 | Datasheet: | |
13 | ||
14 | https://www.analog.com/media/en/technical-documentation/data-sheets/LTC2947.pdf | |
15 | ||
16 | Author: Nuno Sá <[email protected]> | |
17 | ||
18 | Description | |
19 | ___________ | |
20 | ||
21 | The LTC2947 is a high precision power and energy monitor that measures current, | |
22 | voltage, power, temperature, charge and energy. The device supports both SPI | |
23 | and I2C depending on the chip configuration. | |
24 | The device also measures accumulated quantities as energy. It has two banks of | |
25 | register's to read/set energy related values. These banks can be configured | |
26 | independently to have setups like: energy1 accumulates always and enrgy2 only | |
27 | accumulates if current is positive (to check battery charging efficiency for | |
28 | example). The device also supports a GPIO pin that can be configured as output | |
29 | to control a fan as a function of measured temperature. Then, the GPIO becomes | |
30 | active as soon as a temperature reading is higher than a defined threshold. The | |
31 | temp2 channel is used to control this thresholds and to read the respective | |
32 | alarms. | |
33 | ||
34 | Sysfs entries | |
35 | _____________ | |
36 | ||
37 | The following attributes are supported. Limits are read-write, reset_history | |
38 | is write-only and all the other attributes are read-only. | |
39 | ||
40 | ======================= ========================================== | |
41 | in0_input VP-VM voltage (mV). | |
42 | in0_min Undervoltage threshold | |
43 | in0_max Overvoltage threshold | |
44 | in0_lowest Lowest measured voltage | |
45 | in0_highest Highest measured voltage | |
46 | in0_reset_history Write 1 to reset in1 history | |
47 | in0_min_alarm Undervoltage alarm | |
48 | in0_max_alarm Overvoltage alarm | |
49 | in0_label Channel label (VP-VM) | |
50 | ||
51 | in1_input DVCC voltage (mV) | |
52 | in1_min Undervoltage threshold | |
53 | in1_max Overvoltage threshold | |
54 | in1_lowest Lowest measured voltage | |
55 | in1_highest Highest measured voltage | |
56 | in1_reset_history Write 1 to reset in2 history | |
57 | in1_min_alarm Undervoltage alarm | |
58 | in1_max_alarm Overvoltage alarm | |
59 | in1_label Channel label (DVCC) | |
60 | ||
61 | curr1_input IP-IM Sense current (mA) | |
62 | curr1_min Undercurrent threshold | |
63 | curr1_max Overcurrent threshold | |
64 | curr1_lowest Lowest measured current | |
65 | curr1_highest Highest measured current | |
66 | curr1_reset_history Write 1 to reset curr1 history | |
67 | curr1_min_alarm Undercurrent alarm | |
68 | curr1_max_alarm Overcurrent alarm | |
69 | curr1_label Channel label (IP-IM) | |
70 | ||
71 | power1_input Power (in uW) | |
72 | power1_min Low power threshold | |
73 | power1_max High power threshold | |
74 | power1_input_lowest Historical minimum power use | |
75 | power1_input_highest Historical maximum power use | |
76 | power1_reset_history Write 1 to reset power1 history | |
77 | power1_min_alarm Low power alarm | |
78 | power1_max_alarm High power alarm | |
79 | power1_label Channel label (Power) | |
80 | ||
81 | temp1_input Chip Temperature (in milliC) | |
82 | temp1_min Low temperature threshold | |
83 | temp1_max High temperature threshold | |
84 | temp1_input_lowest Historical minimum temperature use | |
85 | temp1_input_highest Historical maximum temperature use | |
86 | temp1_reset_history Write 1 to reset temp1 history | |
87 | temp1_min_alarm Low temperature alarm | |
88 | temp1_max_alarm High temperature alarm | |
89 | temp1_label Channel label (Ambient) | |
90 | ||
91 | temp2_min Low temperature threshold for fan control | |
92 | temp2_max High temperature threshold for fan control | |
93 | temp2_min_alarm Low temperature fan control alarm | |
94 | temp2_max_alarm High temperature fan control alarm | |
95 | temp2_label Channel label (TEMPFAN) | |
96 | ||
97 | energy1_input Measured energy over time (in microJoule) | |
98 | ||