/* FIXME: cagney/2003-04-13: Can't yet use gdbarch_num_regs
(gdbarch), as not all architectures are multi-arch. */
raw_p = rawnum < gdbarch_num_regs (current_gdbarch);
- if (REGISTER_NAME (regnum) == NULL || REGISTER_NAME (regnum)[0] == '\0')
+ if (gdbarch_register_name (current_gdbarch, regnum) == NULL
+ || gdbarch_register_name (current_gdbarch, regnum)[0] == '\0')
return 0;
if (reggroup == float_reggroup)
return float_p && pseudo;
gdb_byte *raw_buffer = alloca (raw_size);
if (!frame_register_read (frame, regno, raw_buffer))
- error (_("can't read register %d (%s)"), regno, REGISTER_NAME (regno));
+ error (_("can't read register %d (%s)"),
+ regno, gdbarch_register_name (current_gdbarch, regno));
if (raw_size == 8)
{
/* We have a 64-bit value for this register. Find the low-order
/* We have a 64-bit value for this register, and we should use
all 64 bits. */
if (!frame_register_read (frame, regno, rare_buffer))
- error (_("can't read register %d (%s)"), regno, REGISTER_NAME (regno));
+ error (_("can't read register %d (%s)"),
+ regno, gdbarch_register_name (current_gdbarch, regno));
}
else
{
raw_buffer = alloca (2 * register_size (current_gdbarch,
mips_regnum (current_gdbarch)->fp0));
- fprintf_filtered (file, "%s:", REGISTER_NAME (regnum));
- fprintf_filtered (file, "%*s", 4 - (int) strlen (REGISTER_NAME (regnum)),
+ fprintf_filtered (file, "%s:",
+ gdbarch_register_name (current_gdbarch, regnum));
+ fprintf_filtered (file, "%*s",
+ 4 - (int) strlen (gdbarch_register_name
+ (current_gdbarch, regnum)),
"");
if (register_size (current_gdbarch, regnum) == 4 || mips2_fp_compat ())
/* Get the data in raw format. */
if (!frame_register_read (frame, regnum, raw_buffer))
{
- fprintf_filtered (file, "%s: [Invalid]", REGISTER_NAME (regnum));
+ fprintf_filtered (file, "%s: [Invalid]",
+ gdbarch_register_name (current_gdbarch, regnum));
return;
}
- fputs_filtered (REGISTER_NAME (regnum), file);
+ fputs_filtered (gdbarch_register_name (current_gdbarch, regnum), file);
/* The problem with printing numeric register names (r26, etc.) is that
the user can't use them on input. Probably the best solution is to
+ gdbarch_num_pseudo_regs (current_gdbarch);
regnum++)
{
- if (*REGISTER_NAME (regnum) == '\0')
+ if (*gdbarch_register_name (current_gdbarch, regnum) == '\0')
continue; /* unused register */
if (TYPE_CODE (register_type (gdbarch, regnum)) ==
TYPE_CODE_FLT)
fprintf_filtered (file, " ");
fprintf_filtered (file,
mips_abi_regsize (current_gdbarch) == 8 ? "%17s" : "%9s",
- REGISTER_NAME (regnum));
+ gdbarch_register_name (current_gdbarch, regnum));
col++;
}
+ gdbarch_num_pseudo_regs (current_gdbarch);
regnum++)
{
- if (*REGISTER_NAME (regnum) == '\0')
+ if (*gdbarch_register_name (current_gdbarch, regnum) == '\0')
continue; /* unused register */
if (TYPE_CODE (register_type (gdbarch, regnum)) ==
TYPE_CODE_FLT)
break; /* end row: reached FP register */
/* OK: get the data in raw format. */
if (!frame_register_read (frame, regnum, raw_buffer))
- error (_("can't read register %d (%s)"), regnum, REGISTER_NAME (regnum));
+ error (_("can't read register %d (%s)"),
+ regnum, gdbarch_register_name (current_gdbarch, regnum));
/* pad small registers */
for (byte = 0;
byte < (mips_abi_regsize (current_gdbarch)
if (regnum != -1) /* do one specified register */
{
gdb_assert (regnum >= gdbarch_num_regs (current_gdbarch));
- if (*(REGISTER_NAME (regnum)) == '\0')
+ if (*(gdbarch_register_name (current_gdbarch, regnum)) == '\0')
error (_("Not a valid register for the current processor type"));
mips_print_register (file, frame, regnum, 0);
/* FIXME: cagney/2002-05-13: Need to look at the pseudo register to
decide if it is valid. Should instead define a standard sim/gdb
register numbering scheme. */
- if (REGISTER_NAME (gdbarch_num_regs (current_gdbarch) + regnum) != NULL
- && REGISTER_NAME (gdbarch_num_regs (current_gdbarch) + regnum)[0] != '\0')
+ if (gdbarch_register_name (current_gdbarch,
+ gdbarch_num_regs
+ (current_gdbarch) + regnum) != NULL
+ && gdbarch_register_name (current_gdbarch,
+ gdbarch_num_regs
+ (current_gdbarch) + regnum)[0] != '\0')
return regnum;
else
return LEGACY_SIM_REGNO_IGNORE;